Anbieter: Istar Dental Supply

Dental Autoclave Sterilizer, 4.3’’ Colour Screen, Fully Automatic Autoclave Machine For Dental Clinic, 18L/23L

1.279,89 €2.037,28 €37% OFF
Volume: 18L
Menge

Beschreibung

Features:

4.3 inch TFT colour screen

Precise touch screen control, simple, innovative and practical.

Intelligent monitoring and diagnosis system

Real-time monitoring of the entire sterilization operating system. Once a fault occurs, the intelligent diagnosis system can find the faulty parts in sections, and can directly retrieve the fault information and simple solutions, so that the repair accuracy reaches 100%, making maintenance more convenient. This intelligent diagnosis system is like a "real technical character" with real-time diagnosis and intervention capabilities.

Good traceability

Standard large-capacity storage to realize automatic storage and retrieval of sterilization data. An optional external thermal printer can automatically print the sterilization data and sterilization results after each sterilization program is completed.

Preheating system

The preheating standby function keeps the temperature above the minimum temperature at all times, making the program run faster and more energy-efficient.

Super large air-conditioning heat dissipation window

260x142mm open heat storage, strong power, 73 layers of heat dissipation aluminum plate and 18 heat dissipation pipes, efficient condensation, ensure that hot water is instantly cooled to normal, and protect the drainage channel.

Quick drainage system

The imported quick interface, located at the front of the sterilizer, makes the work of adding water and draining water extremely simple and fast. Moreover, the water gate is automatically discharged directly, which effectively prevents the pollution of the internal water system of the chrysanthemum destroyer. Not only that, it can also be equipped with an automatic water filling system to realize automatic water supply from the external water tank.

Futuristic handle

Give you a different visual experience, enjoy the technology comfortably.

Built-in open water tank

The 3.5L large-capacity water tank can meet the water needs of 5 sterilization cycles. The fully open water tank can be monitored and easily cleaned. It is easy to check the water quality in the tank and facilitate daily cleaning and disinfection.

Parameter:

Applicable voltage

220-240 VAC-50/60Hz, single-phase voltage

Rated voltage

220V, 50Hz

Maximum current

10A

Maximum altitude

Altitude 2000 meters

Maximum working pressure

2.5 Bar(250 kPa)

Minimum working pressure

-0.9 Bar(-90 kpa)

Minimum atmospheric pressure

0.7bar

Maximum temperature

<145°C

Dimensions

585x438x405mm(Novo Pro 18L)

685x438x405mm(Novo Pro 23L)

Full load weight

≈50 kg(Novo Pro 18L)

≈60kg(Novo Pro 23L)

Safety threshold

2.45 bar (compliant with YY0154-2013 and YY/T0157-2013)

Vacuum degree

>-0.08Mpa

Noise level

<80 DB

Total volume of the pot

245 mm xD355 mm(Novo Pro 18L)

245 mmxD445 mm(Novo Pro 23L)

Usable pot volume

198 mmx204mmx319mm(Novo Pro 18L)

198 mmx204mmx385mm(Novo Pro 23L)

Steam filter

Filtration efficiency of particles above 0.3μm is not less than 99.5%

Water quality requirements

EC(conductivity <15uS/cm)

Average water consumption per cycle

Novo Pro 18L:0.15L(minimum) 0.26L(maximum)

Novo Pro 23L:0.17L(minimum)0.31L(maximum)

Water tank volume

Water tank 3.5L

Procedures

Load Types

Sterilization Type

Temperature (℃)

Sterilization Time (Minutes)

Drying Time (Minutes)

Solid Instruments

Solid Instruments

S

134/121

10/30

9

Rapid Sterilization

Emergency Sterilization Of Bare Instruments/Rubber

S

134/121

4/20

4

Porous Instruments

Solid And Hollow Loads, Cotton Ball Fabric

B

134/121

5/20

18

Wrapped Instruments

Cotton Ball Fabric, Wrapped Instruments, Hollow Loads

B

134/121

18/30

18

 Precautions:

1. Do not add any water with chemical or similar ingredients to the steriliser.
2. Do not sterilise volatile substances, toxic materials or other unsuitable equipment.
3. Do not place the steriliser in direct sunlight.
4. Do not place the steriliser on heat sensitive surfaces.
5. Cleaning with unsuitable materials.
6. Misuse the steriliser.
7. Use the steriliser in an area where it is likely to come into contact with flammable materials or gases.
8. In order to ensure the quality of sterilisation of instruments after 6 months of use or 200 cycles of operation, please replace the air filter in a timely manner.

Troubleshooting:

Error Code

Cause Of Error

LCD Prompt Message

Solution

CODE1

The pressure did not reach the set value after heating up and boosting for 30 minutes

Error: 01 Slow heating

1. Steam generator is damaged

2. Severe air leakage in the cabin door

3. The balance valve is incorrectly opened

4. The drainage valve is incorrectly started

5. The voltage is seriously low

CODE2

In the process of heating up or sterilization, the pressure is greater than the set pressure

Error: 02 Too much pressure

1. The internal temperature sensor is faulty

2. The vacuum pump is faulty

3. The solenoid valve leaks
Altitude setting error

CODE3

Door opening detected during operation

Error: 03 Door lock is open

1. Door lock switch is not good

2. Clearance between hatch and pan body

CODE4

The pressure is less than the set pressure in the process of heating up or sterilization

Error: 04 Pressure is too low

1. The internal temperature sensor is faulty

2. The solenoid valve leaks
Altitude setting error

CODE5

In the vacuum process, the exhaust within 20 minutes (the first vacuum is 30 minutes) failed to reach 20kpa, and the exhaust failed to reach 20kpa in 25 minutes after the completion of sterilization

Error: 05 Abnormal pressure relief

1. The altitude setting is incorrect

2. The pipe is blocked
Defective solenoid valve

CODE6

The vacuum process failed to reach -0.4bar for 5 minutes, and the leak test failed to reach -0.6bar

Error: 06 Slow vacuum speed

1. Poor seal

2. The vacuum pump is faulty

3. The altitude setting is incorrect

4. Defective solenoid valve

CODE7

Ambient atmospheric pressure < 0.7bar was detected

Error: 07 Low ambient pressure

1. The altitude setting is incorrect

2. Pressure sensor failure

CODE8

Door lock switch logic detection error

Error: 08 Door opening error

1. The door opening switch is broken

2. Poor motor

CODE9

Motor running error

Error: 09 Closed the door incorrectly

1. The door close switch is broken

2. Poor motor

CODE10

Preheat for 20 minutes, the wall temperature < 100 degrees Celsius, the generator temperature < 110 degrees Celsius

Error: 10 Full preheat

1. Bad steam generator

2. Bad heater

CODE11

The temperature exceeds the theoretical +2 degrees or exceeds the maximum required by the specification during the heating and pressure boost or sterilization process

Error: 12 The temperature is too high

1.The internal temperature sensor is faulty

2. The voltage is abnormal

3. The vacuum pump is faulty

4. Solenoid valve leakage

CODE12

In the process of heating up or sterilization, the temperature is lower than the theoretical temperature of -2 degrees or exceeds the minimum required by the specification

Error: 12 The temperature is too low

1. The internal temperature sensor is faulty

2. Voltage anomaly

CODE13

Add water more than 3 minutes for low water level, or less than 4.5 minutes

Error: 13 The time for adding water exceeds the limit

1. The water pump is damaged

2. The water level switch is broken

3. The device does not support automatic water addition

4. Check the configuration bit