Dental Autoclave Sterilizer, 4.3’’ Colour Screen, Fully Automatic Autoclave Machine For Dental Clinic, 18L/23L
Beschreibung
Features:
4.3 inch TFT colour screen
Precise touch screen control, simple, innovative and practical.
Intelligent monitoring and diagnosis system
Real-time monitoring of the entire sterilization operating system. Once a fault occurs, the intelligent diagnosis system can find the faulty parts in sections, and can directly retrieve the fault information and simple solutions, so that the repair accuracy reaches 100%, making maintenance more convenient. This intelligent diagnosis system is like a "real technical character" with real-time diagnosis and intervention capabilities.
Good traceability
Standard large-capacity storage to realize automatic storage and retrieval of sterilization data. An optional external thermal printer can automatically print the sterilization data and sterilization results after each sterilization program is completed.
Preheating system
The preheating standby function keeps the temperature above the minimum temperature at all times, making the program run faster and more energy-efficient.
Super large air-conditioning heat dissipation window
260x142mm open heat storage, strong power, 73 layers of heat dissipation aluminum plate and 18 heat dissipation pipes, efficient condensation, ensure that hot water is instantly cooled to normal, and protect the drainage channel.
Quick drainage system
The imported quick interface, located at the front of the sterilizer, makes the work of adding water and draining water extremely simple and fast. Moreover, the water gate is automatically discharged directly, which effectively prevents the pollution of the internal water system of the chrysanthemum destroyer. Not only that, it can also be equipped with an automatic water filling system to realize automatic water supply from the external water tank.
Futuristic handle
Give you a different visual experience, enjoy the technology comfortably.
Built-in open water tank
The 3.5L large-capacity water tank can meet the water needs of 5 sterilization cycles. The fully open water tank can be monitored and easily cleaned. It is easy to check the water quality in the tank and facilitate daily cleaning and disinfection.
Parameter:
|
Applicable voltage |
220-240 VAC-50/60Hz, single-phase voltage |
|
Rated voltage |
220V, 50Hz |
|
Maximum current |
10A |
|
Maximum altitude |
Altitude 2000 meters |
|
Maximum working pressure |
2.5 Bar(250 kPa) |
|
Minimum working pressure |
-0.9 Bar(-90 kpa) |
|
Minimum atmospheric pressure |
0.7bar |
|
Maximum temperature |
<145°C |
|
Dimensions |
585x438x405mm(Novo Pro 18L) 685x438x405mm(Novo Pro 23L) |
|
Full load weight |
≈50 kg(Novo Pro 18L) ≈60kg(Novo Pro 23L) |
|
Safety threshold |
2.45 bar (compliant with YY0154-2013 and YY/T0157-2013) |
|
Vacuum degree |
>-0.08Mpa |
|
Noise level |
<80 DB |
|
Total volume of the pot |
245 mm xD355 mm(Novo Pro 18L) 245 mmxD445 mm(Novo Pro 23L) |
|
Usable pot volume |
198 mmx204mmx319mm(Novo Pro 18L) 198 mmx204mmx385mm(Novo Pro 23L) |
|
Steam filter |
Filtration efficiency of particles above 0.3μm is not less than 99.5% |
|
Water quality requirements |
EC(conductivity <15uS/cm) |
|
Average water consumption per cycle |
Novo Pro 18L:0.15L(minimum) 0.26L(maximum) Novo Pro 23L:0.17L(minimum)0.31L(maximum) |
|
Water tank volume |
Water tank 3.5L |
|
Procedures |
Load Types |
Sterilization Type |
Temperature (℃) |
Sterilization Time (Minutes) |
Drying Time (Minutes) |
|
Solid Instruments |
Solid Instruments |
S |
134/121 |
10/30 |
9 |
|
Rapid Sterilization |
Emergency Sterilization Of Bare Instruments/Rubber |
S |
134/121 |
4/20 |
4 |
|
Porous Instruments |
Solid And Hollow Loads, Cotton Ball Fabric |
B |
134/121 |
5/20 |
18 |
|
Wrapped Instruments |
Cotton Ball Fabric, Wrapped Instruments, Hollow Loads |
B |
134/121 |
18/30 |
18 |
Precautions:
1. Do not add any water with chemical or similar ingredients to the steriliser.
2. Do not sterilise volatile substances, toxic materials or other unsuitable equipment.
3. Do not place the steriliser in direct sunlight.
4. Do not place the steriliser on heat sensitive surfaces.
5. Cleaning with unsuitable materials.
6. Misuse the steriliser.
7. Use the steriliser in an area where it is likely to come into contact with flammable materials or gases.
8. In order to ensure the quality of sterilisation of instruments after 6 months of use or 200 cycles of operation, please replace the air filter in a timely manner.
Troubleshooting:
|
Error Code |
Cause Of Error |
LCD Prompt Message |
Solution |
|
CODE1 |
The pressure did not reach the set value after heating up and boosting for 30 minutes |
Error: 01 Slow heating |
1. Steam generator is damaged 2. Severe air leakage in the cabin door 3. The balance valve is incorrectly opened 4. The drainage valve is incorrectly started 5. The voltage is seriously low |
|
CODE2 |
In the process of heating up or sterilization, the pressure is greater than the set pressure |
Error: 02 Too much pressure |
1. The internal temperature sensor is faulty 2. The vacuum pump is faulty 3. The solenoid valve leaks |
|
CODE3 |
Door opening detected during operation |
Error: 03 Door lock is open |
1. Door lock switch is not good 2. Clearance between hatch and pan body |
|
CODE4 |
The pressure is less than the set pressure in the process of heating up or sterilization |
Error: 04 Pressure is too low |
1. The internal temperature sensor is faulty 2. The solenoid valve leaks |
|
CODE5 |
In the vacuum process, the exhaust within 20 minutes (the first vacuum is 30 minutes) failed to reach 20kpa, and the exhaust failed to reach 20kpa in 25 minutes after the completion of sterilization |
Error: 05 Abnormal pressure relief |
1. The altitude setting is incorrect 2. The pipe is blocked |
|
CODE6 |
The vacuum process failed to reach -0.4bar for 5 minutes, and the leak test failed to reach -0.6bar |
Error: 06 Slow vacuum speed |
1. Poor seal 2. The vacuum pump is faulty 3. The altitude setting is incorrect 4. Defective solenoid valve |
|
CODE7 |
Ambient atmospheric pressure < 0.7bar was detected |
Error: 07 Low ambient pressure |
1. The altitude setting is incorrect 2. Pressure sensor failure |
|
CODE8 |
Door lock switch logic detection error |
Error: 08 Door opening error |
1. The door opening switch is broken 2. Poor motor |
|
CODE9 |
Motor running error |
Error: 09 Closed the door incorrectly |
1. The door close switch is broken 2. Poor motor |
|
CODE10 |
Preheat for 20 minutes, the wall temperature < 100 degrees Celsius, the generator temperature < 110 degrees Celsius |
Error: 10 Full preheat |
1. Bad steam generator 2. Bad heater |
|
CODE11 |
The temperature exceeds the theoretical +2 degrees or exceeds the maximum required by the specification during the heating and pressure boost or sterilization process |
Error: 12 The temperature is too high |
1.The internal temperature sensor is faulty 2. The voltage is abnormal 3. The vacuum pump is faulty 4. Solenoid valve leakage |
|
CODE12 |
In the process of heating up or sterilization, the temperature is lower than the theoretical temperature of -2 degrees or exceeds the minimum required by the specification |
Error: 12 The temperature is too low |
1. The internal temperature sensor is faulty 2. Voltage anomaly |
|
CODE13 |
Add water more than 3 minutes for low water level, or less than 4.5 minutes |
Error: 13 The time for adding water exceeds the limit |
1. The water pump is damaged 2. The water level switch is broken 3. The device does not support automatic water addition 4. Check the configuration bit |